Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
Position首页 > Home > Industrial Safety Products > Safety Controller > Safety PLC
Bus gateway


Method for selecting safety controller

Please follow the steps to select the suitable GC series products according to the purpose.

1731372439768371.png1731372445452256.png1731372453953979.png
Selection of main controller [required]

Selection of expansion unit [option]

Selection of bus gateway [option]

1740382230296434.png

1740382254643569.png 网关1.png

SPC-1000

SPC-SIO8          SPC-SIO12SPC-WG


Bus gateway

1732169775923528.png

• It is a bus-type gateway slave device.
• support Modbus、EtherCAT、PROFINET、 EtherNet/IP、CANopen Equal communication 

• Used in conjunction with the safety control modules
• Through the gateway equipment, users can read the logic state information of the safety control module, the running state information of the equipment and the fault alarm state of each IO module in real time, so as to realize remote communication and facilitate operation.


Attachment specification

product name

model

communication method

gateway

SPC-PN

PROFINET

gateway

SPC-MOD

Modbus

gateway

SPC-EIP

Ethernet/IP

gateway

SPC-ECAT

Ether CAT

gateway

SPC-CAN

Canopen


Technical parameter

model

SPC-WG

power indicator

off:Module is power-off

on:Module is power-on

Backplane bus indicator

on:Backplane bus communication is normal.

Blinking:The connection is normal, with some modules offline in the system.

Flickering:Gateway module is offline

Bus operation indicator

off:No connection established with the master station.

on:Successful connection with the master station.

ERR indicator

off:No error (indicator is off)

on:System error (indicator is on)

LiLink/Act

off:No EtherCAT connection

on: Connection is normal,no data.

Flash: Data is being transmitted


Gateway accessory specification

product name

Product selection

use

DIN rail bus connector

SPC-TBUS

A bus connector used to connect the housing of electronic modules, one is required for each module.

Limit switch

SPC-E

A set of two is standard, which is used to fix the module and prevent the module from loosening.

SPC-WG functional block diagram, typical application and outline dimension diagram

Functional block diagram

DIN rail bus connector SPC-TBUS outline dimension diagramLimit switch SPC-E outline dimension diagram
网关.png

SPC-TBUS.png

spc-TBUS外形尺寸.png

SPC-E.png

SPC-E外形尺寸.png



Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright © Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh